Westerbeke 38B FOUR Operator's Manual Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 86
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
Generator Frequency
Frequency is a direct result
of
engine/generator speed:
1800 RPM - 60 Hertz
1500 RPM - 50 Hertz
To change the generator's frequency, refer to the "MAINTENANCE AND ADmSTMENTS" section
of
this manual.
Load Connections
The generator's data plate gives the voltage, current and frequency rating
of
the generator. An AC wiring
decal is affixed to the inside
of
the louvered cover on the generator end. A diagram
of
the various
AC
voltage connections is provided on the decal. The information on the decal is similar to the figure shown
on the following page.
The generator is a single-phase, reconnectable
120
volts AC two-wire or
1201240
volts AC three-wire, at
60 Hertz; or 110 volts
AC
two-wire,
1101220
volts
AC
three-wire, or 220 volts AC two-wire,
at
50 Hertz.
Refer to the
"SYSTEM SPECIFICATIONS" section
of
this manual for ratings, located
at
the beginning of
this manual.
WESTERBEKE GENERATORS 54
Page view 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 85 86

Comments to this Manuals

No comments